NetShelter Rack PDU Advanced Switched 17.3kW 3PH 415V 30A 530P6 48 Outlet

NetShelter Rack PDU Advanced Switched 17.3kW 3PH 415V 30A 530P6 48 Outlet

Part Number:
APDU10350SW
Language:
NS

£2,223.28  (Excl VAT)

Introduction

APC NetShelter Rack PDU Advanced, Switched, 17.3kW, 3PH, 415V, 30A, 530P6, 48 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Design

PDU types

Switched

Type

Three-phase

Rack capacity

0U

Mounting

Vertical

Product colour

Black

Display

LCD

On/off switch

N

Ports & interfaces

AC outlets quantity

24 AC outlet(s)

Power plug

IEC 60309

AC outlet types

C13 coupler, C15 coupler, C19 coupler, C21 coupler

Features

Daisy chain

Y

Certification

CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1

Power

Nominal input voltage

240V

AC input frequency

50/60 Hz

Maximum current

24 A

Nominal output voltage

240 V

Load capacity

17300 VA

Maximum input current per phase

30 A

Maximum total current draw per phase

24 A

Weight & dimensions

Width

56 mm

Depth

75 mm

Height

1780 mm

Weight

9.6 kg

Packaging data

Package weight

12.6 kg

Package width

262 mm

Package depth

132 mm

Package height

1980 mm

Operational conditions

Operating temperature (T-T)

-5 - 60 °C

Storage temperature (T-T)

-25 - 65 °C

Operating relative humidity (H-H)

5 - 95%

Storage relative humidity (H-H)

5 - 95%

Operating altitude

0 - 3048 m

Non-operating altitude

0 - 15240 m